bolt Generators module

Generator monitoring straight from the controller

A cloudGPS device connects to the generator controller and sends the portal what the panel sees: state and mode, alarms, voltage and current per phase, kWh, engine speed, oil pressure, temperature, battery voltage, engine hours and fuel.

A generator in the client portal

Controller data, power per phase, fuel and period totals in one card.

How it works

A device at the controller, data in the portal, calculations on the server.

01 memory

A device at the controller

A compact cloudGPS device goes into the generator cabinet and connects to the controller with one cable. It is powered from the generator battery.

02 visibility

Read only

The device reads data the same way the manufacturer's service software does and changes nothing in the controller. Generator settings and protections stay as they were.

03 wifi

Connectivity

Data goes over the site Wi-Fi or through a GPS tracker nearby over Bluetooth. Without a connection, records are stored in the device and arrive later with exact timestamps.

04 notifications_active

Alerts

Controller alarms, start, stop, overload and phase loss reach the portal, app push, email, Telegram and Viber.

Compatible generator controllers

The device reads data from control panels of these brands. Your model is not listed? Tell us and we will add it.

BrandControllers
SmartGenHGM6100N (HGM6110N, HGM6120N), HGM9000
DatakomD-100, D-300, D-500, D-700, DKG
ComApInteliLite 4 (AMF8, AMF9, AMF20, AMF25), InteliLite 3
Deep Sea ElectronicsDSE6100 MKIII, DSE7300 MKII
WoodwardeasYgen-1400, easYgen-1800, easYgen-XT
DEIFAGC 150, ASC 150, AGC-4, SGC
CumminsPowerCommand
CaterpillarEMCP 4
FG WilsonPowerWizard
Kohler-SDMOAPM303, APM402, APM403, APM802
HimoinsaCEM8, CEA8, CE7
Lovato ElectricRGK
MebayDC
LIXiSELXC
EmkoTrans
15brands of generator controllers
L1 L2 L3voltage, current and power per phase
kWhenergy per day, week and month
l/kWhfuel used per unit of energy produced

What the client sees

A separate Generators section, a report and alerts.

monitor_heartState and mode

Running, stopped or no link, Auto, Manual or Stop mode, controller model. Power and load against the rating.

warningAlarms and warnings

Active controller alarms and warnings with the same names as on the panel screen, and an alert for each one.

electric_boltPower per phase

Voltage, current, power, cos φ and frequency for every phase, kWh produced per run and per period.

speedEngine

Engine speed, oil pressure, coolant temperature, battery voltage and engine hours from the controller.

local_gas_stationFuel and forecast

Tank level, refuels and drains, fuel per kWh and per hour, how long the fuel will last at the current load.

summarizeGenerators report

Every run from start to stop: time, energy, average and peak power, fuel used, levels and refuels. PDF and Excel, scheduled email delivery.

Alerts

Controller alarms and warnings arrive with the name shown on the panel screen. The server also records starts, stops, overload and phase imbalance itself, and lasting states repeat at most once an hour.

Each client picks channels and recipients in the notification settings.

Controller alarmController warningStartStopStopped under loadEngine running, no voltagePhase lostOverloadPhase imbalanceLong idle run

Two ways to connect

A direct controller connection gives the most data. A generator without a controller is connected with meters through a GPS tracker.

What you seeMeters and fuel sensorDirect controller connection
Controller state, mode and alarmsnoyes
Engine speed, oil pressure, temperature, battery, engine hoursnoyes
Voltage, current and power per phase, kWhyesyes
Run time, starts, idleyesyes
Fuellevel sensor in the tankfrom the controller or a level sensor
Installationa meter on each phase and a sensor in the tankone cable to the controller
Which generatorsany, including those without a controllerwith a controller from the list above

Who it is for

Generators you need to see without driving to the site.

storeStandby power for sites

Shops, warehouses, fuel stations, hospitals, water utilities, residential buildings: a generator with an ATS starts by itself, and the portal shows every start, controller alarms and fuel left.

agricultureIsland generators

Construction sites, farms, remote sites: the generator runs without the grid, so fuel, drains, refill planning and maintenance by engine hours matter most.

handymanRental and service

Alarms, engine hours and load of every generator at the client's site: the service team learns about a problem before the client calls and plans maintenance by running time.

What the generator needs

A controller from the list above and a cloudGPS device in the generator cabinet: one cable to the controller, power from the generator battery. Nothing changes in the controller.

A generator without a controller or with an old panel is connected through a GPS tracker: a meter on each phase and a fuel level sensor in the tank. We will suggest compatible trackers and meters for your equipment.

Protocols and connection addresses

SmartGenDatakomComApDeep SeaCumminsDEIF

Connectivity and storage

The device works over the site Wi-Fi, and where there is no Wi-Fi, a GPS tracker nearby passes the data on over Bluetooth.

While there is no connection, records are kept in the device memory, enough for a day and a half of running or about two weeks idle, and reach the server in order as soon as the link is back. The clock is synced over the internet, so every record has an exact time.

wifi

Maintenance by engine hours

Engine hours come from the controller, so the schedule in the maintenance module follows the real running time of the engine: oil and filter changes, reminders and work history with attachments.

Maintenance and service history

build

Fuel in vehicles and at your own station

Generators and vehicles go through the same fuel analyser. If you dispense fuel for generators from your own tank, the Fuel station section shows intake, dispensing and the balance.

Fuel monitoring

local_gas_station

For integrators and service companies

Generators is a separate portal module: you switch it on for a client and sell it as your own service at your own price. A separate sub-user permission covers the Generators section.

Your clients see generators in the same portal under your brand as their vehicles.

Partner terms

handshake

Questions about generator monitoring

Which generator controllers are supported?

SmartGen, Datakom, ComAp, Deep Sea, Woodward, DEIF, Cummins PowerCommand, Caterpillar EMCP 4, FG Wilson PowerWizard, Kohler-SDMO, Himoinsa, Lovato, Mebay, LIXiSE and Emko: models are in the table above. Tell us your controller model and we will check compatibility.

Can the device harm the controller?

No. The device only reads data, like the manufacturer's service software, changes no settings and sends no start or stop commands. Generator protections and automation work as before.

What if there is no Wi-Fi on site?

A GPS tracker installed nearby passes the data on over Bluetooth. If there is no connection at all, the device stores the records and sends them once the link is back.

What if the generator has no controller?

Such a generator is connected through a GPS tracker with phase meters and a fuel level sensor: run time, load, kWh, fuel and the same alerts, but without alarms and engine data.

How is run time calculated?

From the generator state and the output voltage. Time above 5% of the rating counts as under load, the rest as idle. A gap of more than 10 minutes without a single record does not count as run time.

What does fuel per kWh show?

How many litres of fuel go into each kWh produced. At the same load it stays steady, so a rise is a reason to check the engine, the fuel system or the tank.

How are refuels and drains detected?

With the same fuel analyser as for vehicles: a calm level before and after confirms the event, and the minimum refuel and drain volume is set per tank.

How fast do alerts arrive?

A controller alarm arrives with the next device record. Server events are recorded as soon as the state has held for the set time, so a short voltage spike does not become an alarm. Lasting states repeat at most once an hour.

Are generators visible together with vehicles?

Yes. A generator is a device in the same portal: on the map, in reports and in alerts next to the vehicles, with the same sub-user permissions.

Connect your generators to the portal

Tell us the controller brand and model, how many generators you have and their rating. You can start with one.